ZONECAPACITANCEMULTIPLIER:RESEARCHSPECIAL
Multiplier altering the relative capacitance of the air compared to an empty zone
Name
Type: alphanumeric
Zone or ZoneList Name
Type: list of objects
(
ZONE or
ZONELIST)
If this field is left blank, the multipliers are applied to all the zones not specified
Temperature Capacity Multiplier
Type: real number
Used to alter the capacitance of zone air with respect to heat or temperature
Default: 1.0
Humidity Capacity Multiplier
Type: real number
Used to alter the capacitance of zone air with respect to moisture or humidity ratio
Default: 1.0
Carbon Dioxide Capacity Multiplier
Type: real number
Used to alter the capacitance of zone air with respect to zone air carbon dioxide concentration
Default: 1.0
Generic Contaminant Capacity Multiplier
Type: real number
Used to alter the capacitance of zone air with respect to zone air generic contaminant concentration
Default: 1.0