WINDOWPROPERTY:FRAMEANDDIVIDER
Specifies the dimensions of a window frame, dividers, and inside reveal surfaces. Referenced by the surface objects for exterior windows and glass doors (ref: FenestrationSurface:Detailed, Window, and GlazedDoor).
Name
Type: alphanumeric
Referenced by surfaces that are exterior windows Not used by interzone windows
Frame Width
Type: real number
Width of frame in plane of window Frame width assumed the same on all sides of window
Unit: m
Minimum: 0.0
Maximum: 1.0
Default: 0.0
Frame Outside Projection
Type: real number
Amount that frame projects outward from the outside face of the glazing
Unit: m
Minimum: 0.0
Maximum: 0.5
Default: 0.0
Frame Inside Projection
Type: real number
Amount that frame projects inward from the inside face of the glazing
Unit: m
Minimum: 0.0
Maximum: 0.5
Default: 0.0
Frame Conductance
Type: real number
Effective conductance of frame Excludes air films Obtained from WINDOW 5 or other 2-D calculation
Unit: W/m2-K
Minimum: 0.0
Ratio of Frame-Edge Glass Conductance to Center-Of-Glass Conductance
Type: real number
Excludes air films; applies only to multipane windows Obtained from WINDOW 5 or other 2-D calculation
Maximum: 4.0
Default: 1.0
Frame Solar Absorptance
Type: real number
Assumed same on outside and inside of frame
Minimum: 0.0
Maximum: 1.0
Default: 0.7
Frame Visible Absorptance
Type: real number
Assumed same on outside and inside of frame
Minimum: 0.0
Maximum: 1.0
Default: 0.7
Frame Thermal Hemispherical Emissivity
Type: real number
Assumed same on outside and inside of frame
Default: 0.9
Divider Type
Type: choice
(DividedLite or Suspended)
Default: DividedLite
Divider Width
Type: real number
Width of dividers in plane of window Width assumed the same for all dividers
Unit: m
Minimum: 0.0
Maximum: 0.5
Default: 0.0
Number of Horizontal Dividers
Type: real number
"Horizontal" means parallel to local window X-axis
Minimum: 0
Default: 0
Number of Vertical Dividers
Type: real number
"Vertical" means parallel to local window Y-axis
Minimum: 0
Default: 0
Divider Outside Projection
Type: real number
Amount that divider projects outward from the outside face of the glazing Outside projection assumed the same for all divider elements
Unit: m
Minimum: 0.0
Maximum: 0.5
Default: 0.0
Divider Inside Projection
Type: real number
Amount that divider projects inward from the inside face of the glazing Inside projection assumed the same for all divider elements
Unit: m
Minimum: 0.0
Maximum: 0.5
Default: 0.0
Divider Conductance
Type: real number
Effective conductance of divider Excludes air films Obtained from WINDOW 5 or other 2-D calculation
Unit: W/m2-K
Minimum: 0.0
Default: 0.0
Ratio of Divider-Edge Glass Conductance to Center-Of-Glass Conductance
Type: real number
Excludes air films Obtained from WINDOW 5 or other 2-D calculation
Maximum: 4.0
Default: 1.0
Divider Solar Absorptance
Type: real number
Assumed same on outside and inside of divider
Minimum: 0.0
Maximum: 1.0
Default: 0.0
Divider Visible Absorptance
Type: real number
Assumed same on outside and inside of divider
Minimum: 0.0
Maximum: 1.0
Default: 0.0
Divider Thermal Hemispherical Emissivity
Type: real number
Assumed same on outside and inside of divider
Default: 0.9
Outside Reveal Solar Absorptance
Type: real number
Minimum: 0.0
Maximum: 1.0
Default: 0.0
Inside Sill Depth
Type: real number
Unit: m
Minimum: 0.0
Maximum: 2.0
Default: 0.0
Inside Sill Solar Absorptance
Type: real number
Minimum: 0.0
Maximum: 1.0
Default: 0.0
Inside Reveal Depth
Distance from plane of inside surface of glazing to plane of inside surface of wall. Outside reveal depth is determined from the geometry of the window and the wall it is on; it is non-zero if the plane of the outside surface of the glazing is set back from the plane of the outside surface of the wall.
Unit: m
Minimum: 0.0
Maximum: 2.0
Default: 0.0
Inside Reveal Solar Absorptance
Type: real number
Minimum: 0.0
Maximum: 1.0
Default: 0.0