SITE:GROUNDTEMPERATURE:UNDISTURBED:FINITEDIFFERENCE
Undisturbed ground temperature object using a detailed finite difference 1-D model
Name
Soil Thermal Conductivity
Type: real number
Unit: W/m-K
Soil Density
Type: real number
Unit: kg/m3
Soil Specific Heat
Type: real number
Unit: J/kg-K
Soil Moisture Content Volume Fraction
Type: real number
Unit: percent
Minimum: 0
Maximum: 100
Default: 30
Soil Moisture Content Volume Fraction at Saturation
Type: real number
Unit: percent
Minimum: 0
Maximum: 100
Default: 50
Evapotranspiration Ground Cover Parameter
Type: real number
This specifies the ground cover effects during evapotranspiration calculations. The value roughly represents the following cases: = 0 : concrete or other solid, non-permeable ground surface material = 0.5 : short grass, much like a manicured lawn = 1 : standard reference state (12 cm grass) = 1.5 : wild growth
Unit: dimensionless
Minimum: 0
Maximum: 1.5
Default: 0.4