ROOMAIR:NODE:AIRFLOWNETWORK:HVACEQUIPMENT
define the zone equipment associated with one particular RoomAir:Node
Name
Type: alphanumeric
ZoneHVAC or Air Terminal Equipment Object Type 1
Type: choice
(ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, ZoneHVAC:EnergyRecoveryVentilator, ZoneHVAC:FourPipeFanCoil, ZoneHVAC:OutdoorAirUnit, ZoneHVAC:PackagedTerminalAirConditioner, ZoneHVAC:PackagedTerminalHeatPump, ZoneHVAC:UnitHeater, ZoneHVAC:UnitVentilator, ZoneHVAC:VentilatedSlab, ZoneHVAC:WaterToAirHeatPump, ZoneHVAC:WindowAirConditioner, ZoneHVAC:Baseboard:RadiantConvective:Electric, ZoneHVAC:Baseboard:RadiantConvective:Water, ZoneHVAC:Baseboard:RadiantConvective:Steam, ZoneHVAC:Baseboard:Convective:Electric, ZoneHVAC:Baseboard:Convective:Water, ZoneHVAC:HighTemperatureRadiant, ZoneHVAC:Dehumidifier:DX, ZoneHVAC:IdealLoadsAirSystem, ZoneHVAC:RefrigerationChillerSet, Fan:ZoneExhaust, WaterHeater:HeatPump, AirTerminal:DualDuct:ConstantVolume, AirTerminal:DualDuct:VAV, AirTerminal:SingleDuct:ConstantVolume:Reheat, AirTerminal:SingleDuct:ConstantVolume:NoReheat, AirTerminal:SingleDuct:VAV:Reheat, AirTerminal:SingleDuct:VAV:NoReheat, AirTerminal:SingleDuct:SeriesPIU:Reheat, AirTerminal:SingleDuct:ParallelPIU:Reheat, AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction, AirTerminal:SingleDuct:VAV:Reheat:VariableSpeedFan, AirTerminal:SingleDuct:VAV:HeatAndCool:Reheat, AirTerminal:SingleDuct:VAV:HeatAndCool:NoReheat, AirTerminal:SingleDuct:ConstantVolume:CooledBeam, AirTerminal:DualDuct:VAV:OutdoorAir or AirLoopHVACReturnAir)
ZoneHVAC or Air Terminal Equipment Object Name 1
Type: alphanumeric
For object type AirLoopHVACReturnAir, then enter zone return air node name
Fraction of Output or Supply Air from HVAC Equipment 1
Type: real number
Minimum: 0.0
Maximum: 1.0
Fraction of Input or Return Air to HVAC Equipment 1
Type: real number
Minimum: 0.0
Maximum: 1.0
ZoneHVAC or Air Terminal Equipment Object Type 2
Type: choice
(ZoneHVAC:TerminalUnit:VariableRefrigerantFlow, ZoneHVAC:EnergyRecoveryVentilator, ZoneHVAC:FourPipeFanCoil, ZoneHVAC:OutdoorAirUnit, ZoneHVAC:PackagedTerminalAirConditioner, ZoneHVAC:PackagedTerminalHeatPump, ZoneHVAC:UnitHeater, ZoneHVAC:UnitVentilator, ZoneHVAC:VentilatedSlab, ZoneHVAC:WaterToAirHeatPump, ZoneHVAC:WindowAirConditioner, ZoneHVAC:Baseboard:RadiantConvective:Electric, ZoneHVAC:Baseboard:RadiantConvective:Water, ZoneHVAC:Baseboard:RadiantConvective:Steam, ZoneHVAC:Baseboard:Convective:Electric, ZoneHVAC:Baseboard:Convective:Water, ZoneHVAC:HighTemperatureRadiant, ZoneHVAC:Dehumidifier:DX, ZoneHVAC:IdealLoadsAirSystem, ZoneHVAC:RefrigerationChillerSet, Fan:ZoneExhaust, WaterHeater:HeatPump, AirTerminal:DualDuct:ConstantVolume, AirTerminal:DualDuct:VAV, AirTerminal:SingleDuct:ConstantVolume:Reheat, AirTerminal:SingleDuct:VAV:Reheat, AirTerminal:SingleDuct:VAV:NoReheat, AirTerminal:SingleDuct:SeriesPIU:Reheat, AirTerminal:SingleDuct:ParallelPIU:Reheat, AirTerminal:SingleDuct:ConstantVolume:FourPipeInduction, AirTerminal:SingleDuct:VAV:Reheat:VariableSpeedFan, AirTerminal:SingleDuct:VAV:HeatAndCool:Reheat, AirTerminal:SingleDuct:VAV:HeatAndCool:NoReheat, AirTerminal:SingleDuct:ConstantVolume:CooledBeam or AirTerminal:DualDuct:VAV:OutdoorAir)
ZoneHVAC or Air Terminal Equipment Object Name 2
Type: alphanumeric
Fraction of Output or Supply Air from HVAC Equipment 2
Type: real number
Minimum: 0.0
Maximum: 1.0
Fraction of Input or Return Air to HVAC Equipment 2
Type: real number
Minimum: 0.0
Maximum: 1.0