GENERATOR:MICROCHP:NONNORMALIZEDPARAMETERS
This object is referenced by a Generator:MicroCHP object and provides the non-normalized parameters for the MicroCHP generator model.
Name
Maximum Electric Power
Unit: W
Minimum Electric Power
Unit: W
Minimum Cooling Water Flow Rate
Unit: kg/s
Maximum Cooling Water Temperature
Unit: C
Electrical Efficiency Curve Name
Type: list of objects
(
CURVE:TRIQUADRATIC,
TABLE:LOOKUP or
CURVE:CHILLERPARTLOADWITHLIFT)
TriQuadratic
Thermal Efficiency Curve Name
Type: list of objects
(
CURVE:TRIQUADRATIC,
TABLE:LOOKUP or
CURVE:CHILLERPARTLOADWITHLIFT)
TriQuadratic
Cooling Water Flow Rate Mode
Type: choice
(PlantControl or InternalControl)
Cooling Water Flow Rate Curve Name
Type: list of objects
(
CURVE:CUBICLINEAR,
CURVE:QUADRATICLINEAR,
CURVE:FANPRESSURERISE,
TABLE:LOOKUP,
CURVE:BIQUADRATIC or
CURVE:BICUBIC)
Air Flow Rate Curve Name
Type: list of objects
(
CURVE:EXPONENTIALSKEWNORMAL,
CURVE:DOUBLEEXPONENTIALDECAY,
CURVE:CUBIC,
CURVE:LINEAR,
CURVE:RECTANGULARHYPERBOLA2,
TABLE:LOOKUP,
CURVE:FUNCTIONAL:PRESSUREDROP,
CURVE:QUARTIC,
CURVE:SIGMOID,
CURVE:EXPONENT,
CURVE:RECTANGULARHYPERBOLA1,
CURVE:QUADRATIC or
CURVE:EXPONENTIALDECAY)
Maximum Net Electrical Power Rate of Change
Unit: W/s
Maximum Fuel Flow Rate of Change
Unit: kg/s2
Heat Exchanger U-Factor Times Area Value
Unit: W/K
Skin Loss U-Factor Times Area Value
Unit: W/K
Skin Loss Radiative Fraction
Type: real number
Aggregated Thermal Mass of Energy Conversion Portion of Generator
Unit: W/K
Aggregated Thermal Mass of Heat Recovery Portion of Generator
Unit: W/K
Standby Power
Unit: W
Warm Up Mode
Type: choice
(NominalEngineTemperature or TimeDelay)
Stirling engines use Nominal Engine Temperature Internal combustion engines use Time Delay
Warm Up Fuel Flow Rate Coefficient
Nominal Engine Operating Temperature
Unit: C
Warm Up Power Coefficient
Warm Up Fuel Flow Rate Limit Ratio
Warm Up Delay Time
Unit: s
Cool Down Power
Unit: W
Cool Down Delay Time
Unit: s
Restart Mode
Type: choice
(MandatoryCoolDown or OptionalCoolDown)